Eco + Paint

 Enercon, The Developers Of Green Technology, Introduces First Of Its Own Kind A Cvm Technology,( Ceramic Vacuum Matrix Technology.) The Tightly Packed Film Reflects And Dissipates Heat By Minimizing The Path For The Transfer Of Heat. The Ceramics Are Able To Reflect, Refract And Block Heat Radiation (Loss Or Gain) And Dissipate Heat Rapidly Preventing Heat Transfer Through The Coating With As Much As 90% Of Solar Infrared Rays And 85% Of Ultra Violet-Rays Being Radiated Back Into The Atmosphere.Eco Is Particularly Useful Where The Terrace Covers As Air Conditioned Space. A Higher Roof Temperature Necessarily Leads To A Higher Load On The Air Conditioning Plant A Reduction In Roof Temperature Will Result In Lower Roof Temperature With Consequent Savings In Power Consumption

Recommended Use :

Concrete, Plaster

AC/GI Sheet etc.,

Primed Metal

 

Technical Information :

Form : Viscous liquid

Colour : Off white, Tintable to any light shade(using suitable stainer )

Sp.Gravity : 1 to 1.2

Solids by weight : 45% to 50%

Dry Film thickness : 45 microns per coat

Temp. Resistance : Withstand up to 1200 C

Fire resistance : 8 Sec. (ISI limit is 20 SEc.)

Water absorption : Nil

Abrasion resistance : 6000 Cycles

Shelf life : Six Months

Coverage : 1 kg. eco# will Cover 25 to 30 sq.ft. area in double coat for smooth surface

 

Advantages:

Ready to use single pack system

Re radiates heat and controls heat transfer

Reduces air-conditioner running cost.

Its coating shields the surface from heat and water

Does not crack due to wide temperature fluctuation

Cleans up with soap and water

 

Special Features:

eco enhances roof durability and reduces both building cooling loads and the urban heat island effect.

eco has excellent abrasion and water resistance it is also resistant to fungal growth.

eco is recommended for reduction in the “carbon foot print” of a building as it reduces fuel consumption of the air-conditioning plant

In general the surface temperature is in the range of 60A°C to 90A°C in summer and this can be substantially reduced by coating the roof. eco typically various types of roofs will show reduction (after coating) of surface temperature as indicated below :

RCC, cement finished surfaces 10A° C to 12A° C

Asbestos cement sheets … 12A° C to 15A° C

powder coated sheets ... Up to 20° C

Does not crack due to wide temperature fluctuation

Cleans up with soap and water

The above figures are indicative and will vary according to ambient atmospheric conditions such as wind velocity etc

Direction For Use:

Application areas to be cleaned with a hard brush ,to remove all dust, weak paint, fungus etc.

Cleaned area to be washed with water.

The surface should be moist before application.

Stir the paint thoroughly before each use

Apply first coat with brush / spray on the cleaned and washed surface

Apply second coat after a gap of at least one hour. Ensure that the coated area does not come in contact with water for at least one hour

After coating, allow it to cure for at least 24 hours

For Best Performance , Apply even number of coats

Best results are obtained when all walls and roofs are coated with eco